Read Consulting was asked to determine the cause of cracking of glass swimming pool tiles. After construction and filling of a new pool, many glass tiles were cracked. For example, there were 1072 glass tiles on one wall were found to be  cracked.

Tile Array on paper backing From Supplier
Representative Edges of Glass Tiles. These are Scribed and Broken Edges
Photomicrograph of a representative failure origin. The failures originated on the scribed edge and were driven by thermal stresses.

Cause of Failure: The tiles cracks initiated on the scribed edges. The driving stress was thermal stresses created by difference in coefficient of thermal expansion between the mounting thin set mortar and the glass tiles.

Examination of new tiles determined the following:

  1. The individual tiles were glued to a paper backing, and, during handling, these tiles could contact each other on the edge and create damage.
  2. The as purchased sheets of tiles had an array of lengths and colors.
  3. The tile edges indicate that the individual pieces were scribed and broken from larger sheets. These edges had rough finishes that can initiate cracking. These tiles have a an edge “flair” that exceeds 1mm. This does not comply with ANSI A137.2 2013 Section 7.1. In addition,  with the inconsistent snap and break edges a, consistent grout line is not possible; therefore, the requirements of Section 7.6 are also not met.
  4. These tiles do not allow a consistent grout line.
  5. These tiles failed the ANSI A137.2 2013 Section 8.2 to 8.4 thermal shock test for glass tiles (i.e. delta T of 100° F).
  6.  A major contributor to cracking may be the fact that the coefficient of epoxy filled thin set 35 to 40 X 10 -6 K-1 which is approximately five times that of glass (9 X 10-6 K-1 
  7. Failure analysis of broken tiles indicate that the failures initiated on the scribed edges. 

Filed Under: Failure Analysis

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Read Consulting Failure Analysis

Thomas L. Read, PhD,
1435 Fulton Road Santa Rosa, CA
Phone: 707-494-5089
email: info@readconsulting.com

  • Home
  • About
  • Experience
  • Expertise
  • Laboratory
  • Failure Analysis
  • Blog
  • White Papers

Read Consulting Failure Analysis

Thomas L. Read, PhD,
1435 Fulton Road Santa Rosa, CA
Phone: 707-494-5089
email: info@readconsulting.com

Connect With Read Consulting

FacebookTwitterLinkedinYouTubeRSS Feed

Registered Professional Engineer

Thomas L. Read, PhD., CEO
Registered Professional Engineer
Certificate No. MF002174
State of California.

Copyright © 2025 Read Consulting · Materials Failure Analysis And Process Engineering