March 29, 2024 By Tom Read Leave a Comment

Tempered glass is often used for shower doors. As a result, there have been numerous shower door failures. Often the glass failure analysis cannot be performed because of the large number of resulting pieces and the inability to locate the pieces associated with the origin. In this failure example tempered glass was used to construct the shower enclosure. The only evidence available to Read Consulting Failure Analysis was various photographs of the failure. Fortunately , because the failure origin is associated with a “butterfly pattern”, the origin was located. The defining photograph appears to show that the interior corner of the shower enclosure was in direct contact with a tile surface. The hard tile could damage the edge of the tempered glass. Additionally, there is a stress riser associated with the glass interior corner. Due to theses deficiencies, this is a poor design.

 

Figure #1; Photograph of a portion of the failed shower enclosure. The failure butterfly is readily visible locating the failure origin.
Figure #2: Closeup of the origin. The origin is at a 90° Interior corner (a stress riser). Additionally, the glass appears to contact the hard tile.

Filed Under: Failure Analysis

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Read Consulting Failure Analysis

Thomas L. Read, PhD,
1435 Fulton Road Santa Rosa, CA
Phone: 707-494-5089
email: info@readconsulting.com

  • Home
  • About
  • Experience
  • Expertise
  • Laboratory
  • Failure Analysis
  • Blog
  • White Papers

Read Consulting Failure Analysis

Thomas L. Read, PhD,
1435 Fulton Road Santa Rosa, CA
Phone: 707-494-5089
email: info@readconsulting.com

Connect With Read Consulting

FacebookTwitterLinkedinYouTubeRSS Feed

Registered Professional Engineer

Thomas L. Read, PhD., CEO
Registered Professional Engineer
Certificate No. MF002174
State of California.

Copyright © 2025 Read Consulting · Materials Failure Analysis And Process Engineering