November 17, 2020 By Tom Read Leave a Comment

A glass failure analysis was performed on a failed oven door made from heat strengthened glass. The glass in the door is connected to the handle with a metal clip placed directly onto the glass. The edges of the clip on the handle were not properly de-burred.

Over time the normal use of the oven allowed penetration of the glass compressive layer by the edge of the clip. Normal use includes opening and closing of the door and differential movement of the glass and metal as a result of the oven heating and cooling.  This was worsened due to the presence of a burr on the metal edge that was in contact with the glass.

Underside of handle. The glass is captured in the metal handle. There is no compliant material isolating the glass from the metal handle.
Low power photo-micro graph of the failure origin that remains in the handle. The failure originates as a fracture mirror that grew slowly before ultimate failure. There was a metal burr found at the origin.
View of the handle showing the origin with respect to the handle that is holding the remainder of the glass.
Photo micro graph of the origin.

 

 

 

 

 

 

 

 

Cause of Failure: The door failed as a result of two factors.

  1. The heat strengthened glass was not isolated from the metal handle.
  2. The metal handle that was in contact with the glass was not properly finished. It had a burr that interacted with the glass surface.

 

Filed Under: Failure Analysis

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Read Consulting Failure Analysis

Thomas L. Read, PhD,
1435 Fulton Road Santa Rosa, CA
Phone: 707-494-5089
email: info@readconsulting.com

  • Home
  • About
  • Experience
  • Expertise
  • Laboratory
  • Failure Analysis
  • Blog
  • White Papers

Read Consulting Failure Analysis

Thomas L. Read, PhD,
1435 Fulton Road Santa Rosa, CA
Phone: 707-494-5089
email: info@readconsulting.com

Connect With Read Consulting

FacebookTwitterLinkedinYouTubeRSS Feed

Registered Professional Engineer

Thomas L. Read, PhD., CEO
Registered Professional Engineer
Certificate No. MF002174
State of California.

Copyright © 2025 Read Consulting · Materials Failure Analysis And Process Engineering